Mining & Data · Case study

Drill & Blast Vibration Monitoring at Oaklands Junction Quarry

Selecting, installing and reviewing a quarry vibration monitoring system.

I recently worked on a drill and blast vibration monitoring project at Holcim’s Oaklands Junction Quarry, a hard-rock quarry north of Melbourne. The practical question behind the work was simple: how do you turn a brief vibration event into a record you can trust and act on?

That starts before the instrument is switched on. You need to know where the measurement matters, what you’re required to measure and how the site will respond when a reading needs attention. Below is the workflow I use to think through those decisions. The equipment examples are for comparison, and the illustrations are generic. No site readings or compliance outcomes are reported here.

Illustration of a portable vibration recorder, ground sensor and microphone at a quarry
Illustrative field setup: a vibration recorder, ground sensor and air-overpressure microphone. This is not a photograph of Oaklands Junction Quarry.

1. Choose the instrument for the job

I start with the quarry’s approved monitoring plan and applicable conditions. They tell me which locations and measurements matter. A three-axis geophone measures ground motion; a compatible air-overpressure microphone measures the pressure pulse in the air. If the plan calls for both, the system needs to record both in the required units and measurement modes. A general-purpose sound meter or a vibration-only logger shouldn’t be assumed to cover both jobs.

Portable blast seismograph
Useful for attended monitoring or when the setup needs to move between approved locations. The Instantel Micromate is an example of a recorder that can pair a three-axis geophone with a compatible air-overpressure microphone.
Remote monitoring station
Useful for repeat monitoring at fixed locations. Look for local storage, remote health checks and a way to recover records if the connection drops. The Svantek SV 803 is an example of a wireless three-axis vibration station. Check air-overpressure capability separately if the plan requires it.
Specialist or multichannel system
Useful when the scope includes additional measurement points or specialist sensors. The Instantel Minimate Pro is one example of a system with a wider choice of compatible sensors.

For a shortlist, compare calibration and local service support, measurement and frequency range, waveform export, weather protection, battery life and connectivity. Ask to see a sample report and retrieve the raw waveform before committing. I’d rather find out at the bench that a file can’t be exported than discover it after a monitoring event.

2. Install and check the station

  1. Confirm the point and access. Use the approved monitoring location and arrange safe access with the quarry team. If the point is unavailable, have any alternative approved and record why the station moved.
  2. Set up the sensors. Install the geophone on a stable surface with firm ground coupling and the orientation required by the approved method and instrument manual. Set up the microphone as specified by its manual and the monitoring plan. Record the location, surface, orientation, station ID and instrument and sensor serial numbers.
  3. Prove the station can record. Check calibration status, power, storage, connections, clock and time zone. Load the approved measurement settings, run the manufacturer’s field check and confirm that a test record can be retrieved. Photograph the setup for the field record, where permitted.

3. Monitor and keep a usable record

Before the event, confirm the station is armed and logging normally. Afterwards, match the record to the event log using the location and timestamp. Save the report and raw waveform together with the field notes, calibration record and any relevant observations. Remote alerts help draw attention to a reading; they don’t replace the original data. If there’s no record, log it as a monitoring gap and investigate. No file does not mean no vibration.

Illustration of a field engineer reviewing three vibration traces on a laptop
Illustrative report review. The screen does not show site data or measured results.

4. Read the report before drawing a conclusion

Start with the basics: the right station, the right event, valid calibration and a complete trace. Look for signs of clipping, poor sensor contact or an unrelated disturbance such as nearby traffic. Treat those as reasons to investigate the record before using it.

Read peak particle velocity (PPV) in mm/s for the required components and check the frequency information where relevant. Use the metric specified in the approved criteria: the highest component and the vector result are different measures. Review air overpressure separately, using the specified measurement and units. Compare valid results with the limits that apply to that monitoring point and review trends only across records that are comparable.

5. Use the data to decide what happens next

A useful monitoring report lets the next person answer three questions: Where did we measure? Can we trust the record? What follow-up does it require?

Further reading: Resources Victoria’s ground vibration and airblast guidance and the ISEE field practice guidelines for blasting seismographs. Follow the approved site plan and equipment manual for field work.